UWTC-NB9-CASS-18-U-12:Wireless Thermocouple and RTD Industrial Probe Assemblies
Stamford CT, USA — Omega’s new Wireless Industrial Thermocouple and RTD Probe Assemblies feature a complete, ready to install, pre-wired sensor and wireless transmitter package.

Each battery powered wireless unit will transmit measurement back to a host receiver up to 120 m (400′) away.

Each unit comes pre-programmed to operate as a Type J, K, T, E, R,S, B, N or C thermocouple or RTD.

When activated the unit will transmit readings continuously at pre-set time intervals that has been programmed by the user during the initial setup and installation.

Each unit measures and transmits: process temperature, ambient temperature, wireless link signal strength and battery condition to the host and is displayed on the PC screen in real time using the provided free software.

Specifications
Thermocouple (TC) Models
Available Types: J, K, T, E, R, S, B, C or N

Thermocouple Measurement Range:
J: -100 to 760°C (-148 to 1400°F)
K: -100 to 1260°C (-148 to 2300°F)
T: -200 to 400°C (-328 to 752°F)
E: -200 to 1000°C (-328 to 1832°F)
R: 260 to 1760°C (500 to 3200°F)
S: 260 to 1760°C (500 to 3200°F)
B: 870 to 1820°C (1598 to 3308°F)
C: 0 to 2315°C (32 to 4200°F)
N: -100 to 1260°C (-148 to 2300°F)
TC Measurement Accuracy:
Type J, K: ±0.5% of reading or ±1.0°C(1.8°F), whichever is greater
Type T, E, N: ±0.5% of reading or ±2.0°C(3.6°F), whichever is greater
Type R, S, B, C: ±0.5% of full scale

TC Measurement Resolution: 1°C/1°F: Type J, K, T, E, N,; 0.5°C: Type R, S, B, C
Cold Junction Compensation: (Automatic): -10 to 70°C (14 to 158°F)

Resistance Temperature Detector (RTD) Models
Available Types: 100Ω (standard), 500Ω , 1000Ω (special order)

Battery Life (Typical):3 years ( 1 sample/minute reading rate @ 25°C (77°F) )

Note: Because of transmission frequency regulations, these products may only be used in the United States, Canada and Europe(please note CE compliance of the specific model for use in Europe).

For more details and ordering information click here.

OMEGA Engineering, INC.
One Omega Drive
Stamford, Connecticut 06907-0047

Tel: (800)-848-4286 or +1 (203)-359-1660
Fax: +1 (203)-359-7700
Email: temp [at] omega.com
Web: www.omega.com

Related Posts with Thumbnails

subscribe to comments RSS

There are no comments for this post

Please, feel free to post your own comment

* these are required fields

This site is powered by WordPress and a customized version of the FREEmium Theme.